http://www.youtube.com/user/kukasystems | http://twitter.com/kuka_systems | http://www.facebook.com/kuka.systems | https://www.xing.com/companies/kukasystemsgmbh | http://de.wikipedia.org/wiki/KUKA_Systems | https://plus.google.com/s/kuka%20systems#100752174533480906367/posts | http://blog.kuka-systems.com
 

KUKA Sun Sim M 2010

 

 
KUKA Sun Sim M 2010

Sun simulator

The pulsed sun simulator KUKA Sun Sim M 2010 is a high-quality measuring instrument for testing crystalline solar modules in production lines or quality management. In automatic production lines, you can test up to 3 modules per minute, or you can use it manually. Connected to your LAN you can monitor your production quality from your office desk and send flasher reports to your customers.

 

Flash unit

  • Xenon flash tube, optimized with optical reflectors
    to fit 1.7 x 1.35 m module area with +/- 3% homogeneity

  • Irradiation level adjustable from 15 - 100%

  • Power electronics for extending flash tube, flash tube
    lifetime up to two times longer than comparable systems

  • Electronics designed for very high reliability

  • 400 kW peak power

  • Only 1000 W power consumption from grid required
 

Controlled electronic load and measuring system

  • 0-180 V, 0-18 A fully software-controlled

  • Temperature and irradiance corrections
    according to IEC 60891
 


Data measuring equipment / guaranteed
accuracy (temperature range: 18-32°)

P module +/- 2% (+ error of reference module)

U module

6 – 180 V
Accuracy: offset +/- 0.3 V, gain +/- 2%


I module

0.1 – 18 A
accuracy: offset: +/- 0.01 A +/- 2%

Sampling 16 bits 330 kS/s (3 µs)
Temperature +/- 1 °C
Test area 3.0 x 2.0 m (with 2.8% homogeneity)
Test room 4.5 x 2.4 x 3.4 m (L x H x W)
Flashes 1000 W/m2 and optionally 200 W/m2 available

Test time

15 s (20 s interval in automatic
production line incl. robot handling)

Flash length 80% - peak - 80%: 3 ms
 

Software

  • Calculations and visualisation of curves
    according to IEC 60891

  • IRef, IPanel, UPanel = f(t)

  • IPanel= f(UPanel)

  • PPanel= f(UPanel)

  • Control of electronic load in 3 µs steps

  • Data storage as flash report in CSV (txt) or Excel®

  • Data storage as measured waveform with STC module
    characteristics in CVS or Excel®

  • Automatic calibration of the reference module

  • Uniformity monitoring of the test plane with
    2 reference cells (optional)
 

Specifications regarding the characteristics and usability of the products do not constitute a warranty of properties. They are intended to serve informative purposes only. Some items of equipment depicted in the illustrations are optional, and are not included in the standard scope of supply. Solely the respective contract of sale shall be binding in respect of the extent of our supplies.
 
 
 
Further information
 
 
 
Print versionPrint version
Share |
 
 
  © Copyright 2012 KUKA Systems Corp. North America All rights reserved